GTA / GTL / ESS SERIES

Transit Area Energy Storage Series

Modular LiFePO4 energy-storage configurations for transit-area and distributed energy projects, covering battery systems and integrated ESS configurations from 31 kWh to 261 kWh.

  • Published GTA, GTL and ESS GTA/GTL model options
  • Air-cooled and liquid-cooled configurations as stated by model
  • CAN / RS485 communication interfaces
  • Model-specific voltage windows from 204.8 VDC to 832 VDC
  • Request a configuration review for the final project design

Send Your Inquiry

YINEN POWER transit-area liquid-cooled energy storage cabinet

CONFIGURE YOUR STORAGE

Transit-area energy storage models

Compare the published capacity and power ranges. Confirm the latest factory datasheet, local grid requirements, installation conditions and final configuration before ordering.

YINEN POWER GTA 31 41 51 kWh energy storage battery

GTA 31 / 41 / 51 kWh

LiFePO41P16S

Battery energy: 31 / 41 / 51 kWh

Nominal voltage: 307.2 / 409.6 / 512 VDC

Cooling: Air cooling

Send Inquiry

YINEN POWER GTA 64 96 112 kWh energy storage battery

GTA 64 / 96 / 112 kWh

LiFePO41P16S

Battery energy: 64 / 96 / 112 kWh

Nominal voltage: 204.8 / 307.2 / 358.4 VDC

Cooling: Air cooling

Send Inquiry

YINEN POWER GTA GTL 128 to 261 kWh energy storage battery

GTA / GTL 128–261 kWh

LiFePO4GTA / GTL

Battery energy: 128 / 160 / 209 / 261 kWh

Nominal voltage: 409.6–832 VDC

Cooling: Air / liquid by model

Send Inquiry

YINEN POWER ESS GTA 25 to 60 kW energy storage system

ESS GTA 25–60 kW

41–62 kWhIP54

Rated power: 25 / 40 / 50 / 60 kVA

Battery energy: 41 / 51 / 51 / 62 kWh

Cooling: Air cooling

Send Inquiry

YINEN POWER ESS GTA 80 to 150 kW energy storage system

ESS GTA 80–150 kW

112–160 kWhIP54

Rated power: 80 / 100 / 125 / 150 kVA

Battery energy: 112 / 144 / 144 / 160 kWh

Cooling: Air cooling

Send Inquiry

YINEN POWER ESS GTL 200 250 kW liquid-cooled energy storage system

ESS GTL 200 / 250 kW

209 / 261 kWhIP54

Rated power: 200 / 250 kVA

Battery energy: 209 / 261 kWh

Cooling: Liquid cooling

Send Inquiry

PRODUCT OVERVIEW

Modular energy storage for project planning

This series groups published modular battery configurations and integrated energy-storage systems. The factory brochure lists LiFePO4 battery chemistry, CAN/RS485 communication, model-specific protection functions and a working-temperature statement of charge 0–55 °C and discharge −20–55 °C.

Final system selection should account for the project load profile, voltage requirements, grid interface, site conditions, required backup duration and applicable local codes.

Published common parameters

Communication: CAN / RS485

Storage temperature: 0–30 °C

Storage duration: 6 months at 25 °C

Relative humidity: 0–95% non-condensing

Maximum operating altitude: < 4000 m

TECHNICAL DATA

Integrated ESS configuration summary

ModelRated powerBattery energyNominal voltageCoolingDimensions (L × W × H)
ESS GTA 25 kW + 41 kWh25 kVA41 kWh409.6 VDCAir800 × 700 × 1950 mm
ESS GTA 40 / 50 kW + 51 kWh40 / 50 kVA51 kWh512 VDCAir800 × 700 × 2200 mm
ESS GTA 60 kW + 62 kWh60 kVA62 kWh614.4 VDCAir800 × 1210 × 1500 mm
ESS GTA 80 kW + 112 kWh80 kVA112 kWh358.4 VDCAir1100 × 1050 × 2100 mm
ESS GTA 100 / 125 kW + 144 kWh100 / 125 kVA144 kWh460.8 VDCAir1300 × 700 × 2200 mm
ESS GTL 200 / 250 kW200 / 250 kVA209 / 261 kWh665.6 / 832 VDCLiquid1370 × 1010 × 1850 / 2330 mm

Specifications are transcribed from the supplied factory brochure and are subject to the latest factory documentation.

APPLICATION SCENARIOS

Suitable project scenarios

Transit-area load support

Evaluate the daily load curve, peak demand and required reserve time for station facilities, service areas and adjacent distributed loads.

Solar-plus-storage coordination

Use the project electrical design to confirm PV integration, inverter/PCS matching, communication interfaces and energy-management logic.

Backup and resilience planning

Define critical circuits, switching arrangements and desired backup duration before selecting a model and system architecture.

Scalable deployment

Review installation space, transportation route, maintenance access and future expansion needs with the final system designer.

COMMON QUESTIONS

Frequently Asked Questions

Which configuration is suitable for my transit-area project?

Provide the load profile, peak demand, required energy capacity, voltage requirement, installation location, operating schedule and destination country. The final configuration should be confirmed against the latest factory documentation.

Are all models air cooled?

No. The GTA battery and ESS GTA configurations shown are listed as air cooled, while the GTL battery and ESS GTL 200/250 kW configurations are listed as liquid cooled.

What communication interfaces are published?

The brochure lists CAN and RS485 communication. Confirm the required protocol and compatibility with the project inverter, PCS or EMS before ordering.

What are the stated environmental limits?

The brochure lists charge operation from 0–55 °C, discharge operation from −20–55 °C, humidity of 0–95% non-condensing and an operating altitude below 4000 m, with derating above 2000 m.

PROJECT CONFIGURATION

Build the right transit-area energy storage system

Share your load profile, voltage requirement, installation location, destination country and quantity for a practical configuration review.

Send Your Inquiry